| Products |
| Records: 65 |
| DMA 4500 Density Meter |
 | Few instruments have the reputation for accuracy, durability, and reliability associated with the legendary digital density meters from Anton Paar. The DMA 4500 continues that proud tradition.
|
| >>more ..... |
|
| DMA 38 |
 | Many years of experience in designing
density meters for fluids has led to this extremely user-friendly instrument. It is easier to use than any conventional hydrometer and accurate to 0.001 g/cm3. |
| >>more ..... |
|
| DMA 5000 Density Meter |
 | The DMA 5000 from Anton Paar is probably the most accurate, highest precision density meter available anywhere - and yet the fastest and easiest to use.
Nowhere else will you find this combination of extreme exactness in measurement in a user friendly atmosphere.
|
| >>more ..... |
|
| DMA 35N Handheld Density Meter |
 | The DMA 35N - portability and power, all in one small package! Designed for use in the most demanding industrial environments, the DMA 35N gives you the density, specific gravity or % concentration of your sample. |
| >>more ..... |
|
| SVM 3000 |
 | … combines the accuracy of an Ubbelohde capillary viscometer with the speed and ease of use of the internationally recognized density measurement instruments from Anton Paar. |
| >>more ..... |
|
| AMVn |
 | … based on the approved and acknowledged rolling ball/falling ball principle according to DIN 53015 and ISO/DIS 12058 packed in a user friendly and easy to use design. The variable inclination angle of the measurement capillary allows variation of shear stress and shear rate and the built-in Peltier thermostat saves substantial lab space.
|
| >>more ..... |
|
| DSA 5000 |
 | The DSA 5000 measures the density and velocity of sound of liquids to the highest accuracy in wide sample viscosity and temperature ranges.
By combining density and velocity of sound, the concentrations of certain ternary solutions as well as the concentrations of sulphuric acid and oleum in the range of
0 to 100 % H2SO4 and 0 to 65 % SO3 can be measured.
10 individual measuring methods can be selected and edited to calculate numerous density/velocity of sound related units. The measurement data can be stored, printed or sent to a PC or LIMS.
The sample is filled by syringe or by semiautomatic or automatic sample filling systems.
|
| >>more ..... |
|
| BA 2 Beer Analyzer 2 |
 | The Beer Analyzer 2 from Anton Paar combines the measurement of density and sound velocity to perform complete beer analysis. When connected to a sample changer, the beer analyzer is a fully automatic beer measuring system which can analyze up to 24 samples non-stop. |
| >>more ..... |
|
| CKT 100 Thermometer |
 | Thermometer is used for precise callibration of automatical densimeters. Diameter of measurement sensor makes also easy to measure temperature directly in measurement cell with precision 0,001 °C in a range from 0 to 80°C.
|
| >>more ..... |
|
| MKT 25 |
 | This thermometer is ideal tool for measurement of temperature with use resistant probe PT 25. Result is automatically recounted in measurement unit. Combination of MKT 25 reference resistant and callibrated sensor gives tolal uncertaincy of measurement in 0,001°C. |
| >>more ..... |
|
| MKT 100 |
 | This thermometer is used for precise measurement of temperature in laboratory and process conditions with use of process resistant thermometer PT 100. Temperature is calculated according to IEC 751. |
| >>more ..... |
|
| CARBO 2100 Analyzer CO2 |
 | The new Carbo 2100 online CO2 analyzer builds on the strengths of the first Anton Paar online analyzer by using its pressure and temperature method combined with the Impeller principle. The main improvements of the Carbo 2100 are prolonging the time between maintenance intervals and making it suitable for applications under aseptic conditions. Pneumatic valves are now used for opening and closing the measuring chamber, increasing the time between recommended service procedures considerably. These valves also ensure the system is free of any leakage, an essential requirement for aseptic applications. |
| >>more ..... |
|
| COBRIX3 On-line Beverage Analyzer |
 | Continuous and automatic measurement of °Brix, % Diet and carbon dioxide content directly on the soft drink production line is now a reality with the new COBRIX3 multibev On-line Beverage Analyzer. The COBRIX3 provides instantaneous and highly accurate results, requiring minimum supervision and maintenance.
The confidence obtained by its outstanding repeatability along with its drift free performance has established the COBRIX3 as the new standard in on-line beverage quality control measurement. |
| >>more ..... |
|
| SH-1 Sample Handling Unit for DMA 4500/5000 |
 | |
| >>more ..... |
|
| SH-3 Sample Handling Unit for DMA 4500/5000 |
 | The SH-3 takes up hardly any space in the lab: It is built into the DMA 4500/5000, either pre-installed or retrofitted by a service technician. |
| >>more ..... |
|
| DMA 4000 Density/Specific Gravity/Concentration Meter |
 | With the DMA 4000 lab density meter, Anton Paar offers first class performance at an economy class price. Based on more than 30 years of experience as the market leader, Anton Paar has combined outstanding durability, easy operation and fast, reliable measurements into one compact package.
The four-place instrument DMA 4000 is ideal for the many quality control applications found in the food and beverage, chemical, pharmaceutical and petrochemical industries.
The large number of built-in tables allows you to handle most common applications easily. Combined with a sample changer, the DMA 4000 is a very convenient system for measuring many samples automatically.
Up to 48 measuring results can be stored in the instrument and then printed or transferred to a PC or LIMS later.
|
| >>more ..... |
|
| Beer Analyzer 2 |
 | The Beer Analyzer 2 from Anton Paar combines the measurement of density and sound velocity to perform complete beer analysis. When connected to a sample changer, the beer analyzer is a fully automatic beer measuring system which can analyze up to 24 samples non-stop. |
| >>more ..... |
|
| Soft Drink Analyzer 2 |
 | The Soft Drink Analyzer 2 automatically determines actual Brix, fresh Brix and inverted Brix and the degree of inversion from partially or completely inverted samples. Results are delivered after 3 to 5 minutes, compared to the traditional reference method, which is very time and labor intensive. |
| >>more ..... |
|
| DMA 4500 + RXA 156 / RXA 170 Density and Refraction Index Analyzer |
 | Density and refractive index measurements are typically required for the quality control of flavors, fragrances and perfumes as well as in the pharmaceutical industry, beverage industry and petrochemistry. Recognizing these demands, Anton Paar and Dr. Kernchen - each a leading manufacturer in their field - have brought together their latest know-how to offer a combined system for the simultaneous measurement of density and refractive index. The complete system is fully supported and serviced by Anton Paar's worldwide distribution network. |
| >>more ..... |
|
| CarboQC Lab and At-line Beverage Carbonation Meter |
 | The new CarboQC is a portable, robust measuring instrument for the determination of dissolved CO2 in beverages. The analysis is based on the patented Multiple Volume Expansion method to eliminate the influence of other dissolved gases such as air or nitrogen. The instrument is highly accurate, simple to operate, requires low sample volumes and provides rapid results. |
| >>more ..... |
|
| Wine Alcolyzer |
 | The Wine Alcolyzer saves you time in the lab. Just check the Alcolyzer daily with distilled water and occasionally with an ethanol/water mixture and adjust if necssary. Minimal sample preparation is required and the measurement takes approximately 1 minute ensuring a high throughput of samples per hour. Very different samples can be measured immediately after one another without carry-over effects meaning no time-consuming cleaning routines between samples. The Alcolyzer measures the % v/v alcohol content of wine, sparkling wine, cider and rice wine in the range of 0 to 20 % v/v |
| >>more ..... |
|
| Beer Alcolyzer |
 | The Beer Alcolyzer determines the alcohol content of all beers including non-alcoholic beers, beer mixtures, beers during fermentation, finished beers and ciders. Very different samples can be measured immediately after one another without carry-over effects meaning no time-consuming cleaning routines between samples. |
| >>more ..... |
|
| Alcolyzer Plus Beer Analyzing System |
 | One measuring cycle determines all the parameters you require: alcohol (% v/v and % w/w), specific gravity, original extract, real extract, density, degree of fermentation, calories, etc. Color according to EBC and ASBC and pH measurement are optional. The method is MEBAK approved and the alcohol results are comparative to the distillation method. |
| >>more ..... |
|
| Alcolyzer Plus Whisky Analyzing System |
 | The Alcolyzer Plus Whisky determines alcohol %vol, color and pH of alcoholic beverages such as whisky, vodka, gin and rum with an extract content up to approx. 5 g/l. |
| >>more ..... |
|
| SP-1m Sample Changer SP-1m |
 | The automated filling procedure of the SP-1m simplifies the daily measurement of samples with a viscosity of up to 100 mPa.s at ambient temperature. The SP-1m works with a DMA 4000/4500/5000, Beer Analyzer 2, Soft Drink Analyzer 2 and the Alcolyzers. |
| >>more ..... |
|
| SP-3m Sample Changer SP-3m |
 | The SP-3m simplifies the measurement of samples with a viscosity of up to 1000 mPa.s at ambient temperature, e.g. petrochemical samples, volatile samples and samples which require intermediate cleaning of the measuring cell. The SP-3m can be used with a DMA 4000/4500/5000 and the combination DMA 4500/5000 + RXA 156/170. |
| >>more ..... |
|
| SF-1 SF-1 Sample Filling Unit for Alcolyzer/Alcolyzer Plus |
![]() | The SF-1 is designed for maximum ease of use and guarantees highly repeatable and reliable measuring results. It is built into the Alcolyzer/Alcolyzer Plus, so it does not take up extra space on the bench top. Filling parameters are entered through the Alcolyzer or Alcolyzer Plus keyboard. |
| >>more ..... |
|
| DMA 512P External Density Measuring Cell DMA 512P |
 | The DMA 512P measures density and specific gravity at sample pressures up to 700 bar (10 000 psi) and temperatures up to 150 °C (302 °F). The temperature is controled by a separate liquid thermostat.
The DMA 512P can be directly connected to an existing DMA 48/58/60 or DMA 45/46/55 laboratory density meter and connected to DMA 4500/5000 lab density meters and mPDS 1000/2000 evaluation units using interface adapters. |
| >>more ..... |
|
| Physica MCR 51 Physica MCR Rheometer Series |
 | The new Physica MCR Rheometer Series offers four new rheometer models plus an extensive range of accessories which stand out for technical excellence and ease-of-use. Modularity and compatibility across the Physica MCR rheometer series as well as unique features guarantee individual rheometer configurations to solve your application problems at great value for money. |
| >>more ..... |
|
| Physica MCR 101 Physica MCR Rheometer Series |
 | The new Physica MCR Rheometer Series offers four new rheometer models plus an extensive range of accessories which stand out for technical excellence and ease-of-use. Modularity and compatibility across the Physica MCR rheometer series as well as unique features guarantee individual rheometer configurations to solve your application problems at great value for money. |
| >>more ..... |
|
| Physica MCR 301 Physica MCR Rheometer Series |
 | The new Physica MCR Rheometer Series offers four new rheometer models plus an extensive range of accessories which stand out for technical excellence and ease-of-use. Modularity and compatibility across the Physica MCR rheometer series as well as unique features guarantee individual rheometer configurations to solve your application problems at great value for money. |
| >>more ..... |
|
| Physica MCR 501 Physica MCR Rheometer Series |
 | The new Physica MCR Rheometer Series offers four new rheometer models plus an extensive range of accessories which stand out for technical excellence and ease-of-use. Modularity and compatibility across the Physica MCR rheometer series as well as unique features guarantee individual rheometer configurations to solve your application problems at great value for money. |
| >>more ..... |
|
| SmartPave SmartPave Asphalt Rheometer |
 | The new Dynamic Shear Rheometers for asphalt measurements is based on the Physica MCR Rheometer and incorporates new and innovative features that take asphalt testing to previously unattained levels of accuracy, comfort and ease of use. |
| >>more ..... |
|
| Rheolab MC1 |
![]() | The Rheolab MC1 is a portable, modular system with options for use with coaxial cylinders (DIN 53019/ISO 3219), cone/plate and plate/plate geometries (DIN 53018/ISO 3219). It can be connected to a water bath or Peltier thermostat for optimal temperature control. |
| >>more ..... |
|
| Carbo Inline Carbo Inline CO2 Analyzer |
 | The Carbo Inline uses a patented method to ensure there is no influence from oxygen, nitrogen and other gases. The measuring time is just 15 seconds and there is no drift, even before the filler. Carbo Inline is installed directly in the production line and is practical for situations in which a bypass is not possible or desirable and therefore the Carbo 2100 cannot be used. |
| >>more ..... |
|
| mPDS 1000 Evaluation Unit |
 | |
| >>more ..... |
|
| mPDS 2000V3 Evaluation Unit |
 | |
| >>more ..... |
|
| Brix Monitor |
 | Online Brix measurement is crucially important in the production and processing of soft drinks, fruit drinks and syrups. The Online Brix Monitor guarantees accurate readings regardless of whether you are using HFCS, cane sugar or beet sugar. |
| >>more ..... |
|
| Extract Monitor |
 | The extract monitor is used for the accurate online extract measurement at the lauter tub, brewing kettle and after the wort cooler and the measurement of apparent extract at the fermentation tank. |
| >>more ..... |
|
| Alcohol Monitor |
![]() | The Alcohol Monitor determines the alcohol content of alcohol/water mixtures in the range from 0 to 100% and from 0 to 40°C. The alcohol concentration is given in either %v/v or %w/w. |
| >>more ..... |
|
| Beer Monitor |
 | The Beer Monitor determines alcohol content, real and apparent extract, original extract, specific gravity and temperature of beer, alcoholic mix beverages and non-alcoholic beer. |
| >>more ..... |
|
| Original Extract Monitor |
![]() | The Original Extract Monitor is used for the accurate inline determination of original extract and beer temperature. Its short response time allow you to adjust production conditions immediately and keep the product within the desired specifications. The results are automatically compensated for temperature. |
| >>more ..... |
|
| OEM Density module L-DENS/L-DENS TSD |
 | The L-Dens and L-Dens TSD are OEM units which determine density and concentration for integration into measuring instruments or systems. The density measurement is based on the well-known harmonic oscillator technology, which was introduced by Anton Paar more than 30 years ago and which is now the standard method for density measurement worldwide. |
| >>more ..... |
|
| DPRn 407 Density Transducer |
 | |
| >>more ..... |
|
| DTR 407 Density Transmitter |
 | |
| >>more ..... |
|
| DPRn 417 Density Transducer |
 | |
| >>more ..... |
|
| DPRn 427 Density Transducer |
 | |
| >>more ..... |
|
| DTR 427 Density Transmitter |
![]() | |
| >>more ..... |
|
| DPRn 4122 Density Transducer |
 | |
| >>more ..... |
|
| DTR 4122 Density Transmitter |
![]() | |
| >>more ..... |
|
| DPRn 422 Density Transducer |
 | |
| >>more ..... |
|
| DTR 422 Density Transmitter |
 | |
| >>more ..... |
|
| SPRn 4115 Sound Velocity Transducer |
 | |
| >>more ..... |
|
| STR 4115 Sound Velocity Transmitter |
 | |
| >>more ..... |
|
| SPRn 4115L Sound Velocity Transducer |
 | |
| >>more ..... |
|
| STR 4115L Sound Velocity Transmitter |
 | |
| >>more ..... |
|
| SPRn 4215L Sound Velocity Transducer |
 | |
| >>more ..... |
|
| STR 4215L Sound Velocity Transmitter |
 | |
| >>more ..... |
|
| SPRn 4214 Sound Velocity Transducer |
 | |
| >>more ..... |
|
| STR 4214 Sound Velocity Transmitter |
 | |
| >>more ..... |
|
| SPRn 4214LS Sound Velocity Transducer |
 | |
| >>more ..... |
|
| STR 4214LS Sound Velocity Transmitter |
![]() | |
| >>more ..... |
|
| DSRn 427 Density and Sound Velocity Sensor |
![]() | |
| >>more ..... |
|
| Multiwave 3000 |
 | Good sample preparationis of great importance for accurate analysis by AAS, ICP-AES, ICP-MS or voltammetry. It is the most time-consuming and cost-determining step in the analytical process. Thus, in many labs sample preparation is the limiting factor. Anton Paar has been a leading supplier of decomposition instru-ments for more than 25 years. This experience and a thorough understanding of the needs of analytical chemists enable us to offer advanced solutions in sample preparation. We produce instruments with exceptional performance and reliability, which are designed for long-term economic use, manufactured for quality and supported worldwide. Excellent reasons to make Anton Paar your competent partner. We can help you to over-come your sample prep bottleneck! |
| >>more ..... |
|
| CarboIT Carbo IT Inline Transmitter |
 | Anton Paar presents the first inline CO2 transmitter for the continuous measurement and control of the CO2 content during production.
The new CarboIT stands out for short measuring cycles and reliable measurement, even under stop-and-go conditions. The CO2 concentration is shown on the display or available as a 4 - 20 mA analog signal or optional via Profibus. No separate evaluation unit is required.
The CarboIT is mounted directly in the beer production line using a standard flange. The whole system is self-filling and self-emptying, suitable for aseptic applications and CIP compatible. |
| >>more ..... |
|